3kW 5KW Off Off Grid Solar Inverter 110V
3kW 5KW Off Off Grid Solar Inverter 110V
3kW 5KW Off Off Grid Solar Inverter 110V
3kW 5KW Off Off Grid Solar Inverter 110V
1 / 8
3kW 5KW Off Off Grid Solar Inverter 110V
3kW 5KW Off Off Grid Solar Inverter 110V
Casa> Lista de Produto> Inversor solar> Inversor solar 110V> 3kW 5KW Off Off Grid Solar Inverter 110V

3kW 5KW Off Off Grid Solar Inverter 110V

$11,300.00   —  $5,600,000.00 /Set
application
Output Power

Descrição do produto

Atributos do produto

ModeloIGrid MLV 3KW-U

marcaEasun Power

Lugar De OrigemChina

Tipo De Saídasolteiro

Tipos DeInversores DC / AC

Battery Voltage24VDC

Floating Charge Voltage27VDC

Overcharge Protection31VDC

Solar Charger TypeMPPT

Rated Input Voltage110/120Vac

Embalagem & Entrega

Unidades de venda:
Carton

Inversor solar

Descrição do produto

Recursos Introdução:
  • Suporta conexões de bateria de chumbo ácido e íon de lítio
  • Com uma função de ativação dupla quando a bateria de íon de lítio está inativa; O acesso à fonte de alimentação fotovoltaica da rede elétrica pode desencadear a ativação da bateria de íon de lítio.
  • Suporte em fase dividida e saída de onda seno pura de fase monofásica
  • Suporta quatro níveis diferentes de tensão de 100VAC, 105VAC, 110VAC e 120VAC por fase. Suporta duas entradas solares e rastreamento simultâneo de duas funções de capacidade de carregamento/carga máxima de energia solar.
  • MPPT duplo com eficiência de 99,9% e corrente máxima 22A em um único circuito, perfeitamente adaptado aos módulos de alta potência.
  • Função do modo de economia de energia para reduzir as perdas de energia sem carga.
  • 4 Os modos de carregamento estão disponíveis: somente solar, prioridade da rede elétrica, prioridade solar e carregamento misto da rede elétrica/PV.
  • Com dois modos de saída de desvio de utilidade e saída do inversor, com função de fonte de alimentação ininterrupta.
  • Design de diagrama dinâmico de fluxo dinâmico de tela grande LCD, fácil entender o status dos dados e operação do sistema.
  • 3kW Off Off Grid Solar Inverter

EASUN POWER MPPT 3KW 110VAC/120VAC Inverter solar fora da grade no inversor seno

Off Grid Solar InverterOff Grid Solar InverterOff Grid Solar Inverter

Models
ISolar MLV 3KW-U
AC mode
Rated input voltage
110/120VAC
Input voltage range
(90Vac-140Vac)±2%
Frequency
50Hz/ 60Hz (Auto detection)
Frequency Range
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit protection
Circuit breaker
Efficiency
>96%
Conversion time (bypass and inverter)
10ms (typical)
AC reverse protection
Available
Maximum bypass overload current
40A
Inverter mode
Output voltage waveform
Pure sine wave
Rated output power (VA)
3000W
Rated output power (W)
3000W
Power factor
1
Rated output voltage (Vac)
120VAC
Output voltage error
±5%
Output frequency range (Hz)
50Hz ± 0.3Hz/60Hz ± 0.3Hz
Efficiency
>92%


Overload protection
102% < load <110%) ±10%: report error and turn off the output after5 minutes;
(110% < load < 125%) ± 10%: report error and turn off the output after 10 seconds;
Load >125% ±10%: report error and turn offthe output after 5 seconds;
Peak power
4500VA
Loaded motor capability
2HP
Output short circuit protection
Circuit breaker
Bypass breaker specifications
40A
Rated battery input voltage
24V (Minimum starting voltage 22V)

Battery voltage range
20.0Vdc~33Vdc ± 0.6Vdc (Undervoltage alarm/shutdown voltage/overvoltage alarm
overvoltage recovery... settable on LCD screen)
Power saving mode
Load ≤25W
AC charging
Battery type
Lead acid or lithium battery
Maximum charge current
60A
Charge current error
± 5Adc
Charge voltage range
18.0Vdc~33Vdc
Short circuit protection
Circuit breaker and blown fuse
Circuit breaker specifications
40A
Overcharge protection
Alarm and turn off charging after 1 minute
PV charging
Maximum PV open circuit voltage
100VDC
PV operating voltage range
30-100VDC
MPPT voltage range
30-95VDC
Battery voltage range
18-33VDC
Maximum output power
1600W
PV charging current range (can be set)
60A
Charging short circuit protection
Blown fuse
Wiring protection
Reverse polarity protection
Certified specifications
Certification
CE(IEC/EN62109-1,-2)、ROHS2.0
EMC certification level
EN61000
Operating temperature range
-15°C to 55°C
Storage temperature range
-25°C ~ 60°C
Humidity range
5% to 95% (Conformal coating protection)
Noise
≤60dB
Heat dissipation
Forced air cooling, variable speed of fan
Communication interface
USB/RS485(WiFi/GPRS)/Dry node control
Size (L*W*D)
378mm*280mm*103mm
Weight (kg)
6.2

Model
MLV 5KW-U
AC mode
Rated input voltage
110/120Vac
Input voltage range
(90Vac-140Vac) ±2%
Frequency
50Hz/ 60Hz (auto-sensing)
Frequency Range
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit protection
Breaker
Efficiency
>95%
Conversion time (bypass and inverter)
10ms (Typical value)
AC reverse protection
yes
Maximum bypass overload current
63A
Inverting mode
Output voltage waveform
Pure sine wave
Rated output power(VA)
5000
Rated output power(W)
5000
Power factor
1
Rated output voltage (Vac)
120VAC
Output voltage error
±5%
Output frequency range (Hz)
50Hz ± 0.3Hz/60Hz ± 0.3Hz
Efficiency
>90%

Overload protection
(102%<110%) 5 ±10%: reporting error and turn off the output after minutes; (110%<125%) turn
off the output after 10 seconds; Load>125% ±10%: reporting error and turn off
the output after 5 seconds;
Peak power
10000VA
Loaded motor capacity
4HP
Output short-circuit protection
Breaker
Specification of bypass breaker
63A
Rated battery input voltage
48V (minimum start voltage 44V)
Battery voltage range
40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm/turnoff voltage/overvoltage
alarm/overvoltage restoration…settable LCD screen)
Power saving mode
Load ≤25W
AC charge
Battery type
Lead acid or lithium battery
Maximum charge current
40A
Charge current error
± 5Adc
Charge voltage range
40~60Vdc
Short-circuit protection
Breaker and blown fuse
Breaker specification
63A
Overcharge protection
Turn off charge after 1min alarm
Solar charge
Maximum PV opencircuit voltage
500Vdc
PV operation voltage range
120-500Vdc
MPPT voltage range
120-450Vdc
Battery voltage range
40-60Vdc
Maximum output power
5000W
Charge current range of
solar energy (settable)
0-80A
Charge short-circuit protection
Blown fuse
Wiring protection
Inverse wiring protection
Authentication specification
Specification authentication
CE(IEC62109)、RoHs
EMC authentication grade
EN61000
Operation temperature range
-15°C to 55°C
Storage temperature range
-25°C ~ 60°C
Humidity range
5% to 95% (Conformal coating protection)
Noise
≤60dB
Thermal dissipation
Forced cooling with adjustable air speed
Communication interface
USB/RS485 (WiFi/GPRS)/dry node control
Dimension (L*W*D)
426mm*322mm*126mm
Weight (kg)
10.9

Model
MLV 5KW-U
AC mode
Rated input voltage
110/120Vac
Input voltage range
(90Vac-140Vac) ±2%
Frequency
50Hz/ 60Hz (auto-sensing)
Frequency Range
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit protection
Breaker
Efficiency
>95%
Conversion time (bypass and inverter)
10ms (Typical value)
AC reverse protection
yes
Maximum bypass overload current
63A
Inverting mode
Output voltage waveform
Pure sine wave
Rated output power(VA)
5000
Rated output power(W)
5000
Power factor
1
Rated output voltage (Vac)
120VAC
Output voltage error
±5%
Output frequency range (Hz)
50Hz ± 0.3Hz/60Hz ± 0.3Hz
Efficiency
>90%


Overload protection
(102%<110%) 5 ±10%: reporting error and turn off the output after minutes; (110%<125%) turn
off the output after 10 seconds; Load>125% ±10%: reporting error and turn off
the output after 5 seconds;
Peak power
10000VA
Loaded motor capacity
4HP
Output short-circuit protection
Breaker
Specification of bypass breaker
63A
Rated battery input voltage
48V (minimum start voltage 44V)
Battery voltage range
40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm/turnoff voltage/overvoltage
alarm/overvoltage restoration…settable LCD screen)
Power saving mode
Load ≤25W
AC charge
Battery type
Lead acid or lithium battery
Maximum charge current
40A
Charge current error
± 5Adc
Charge voltage range
40~60Vdc
Short-circuit protection
Breaker and blown fuse
Breaker specification
63A
Overcharge protection
Turn off charge after 1min alarm
Solar charge
Maximum PV opencircuit voltage
500Vdc
PV operation voltage range
120-500Vdc
MPPT voltage range
120-450Vdc
Battery voltage range
40-60Vdc
Maximum output power
5000W
Charge current range of
solar energy (settable)
0-80A
Charge short-circuit protection
Blown fuse
Wiring protection
Inverse wiring protection
Authentication specification
Specification authentication
CE(IEC62109)、RoHs
EMC authentication grade
EN61000
Operation temperature range
-15°C to 55°C
Storage temperature range
-25°C ~ 60°C
Humidity range
5% to 95% (Conformal coating protection)
Noise
≤60dB
Thermal dissipation
Forced cooling with adjustable air speed
Communication interface
USB/RS485 (WiFi/GPRS)/dry node control
Dimension (L*W*D)
426mm*322mm*126mm
Weight (kg)
10.9




Produtos quentes

Casa> Lista de Produto> Inversor solar> Inversor solar 110V> 3kW 5KW Off Off Grid Solar Inverter 110V
Lista de produtos relacionados
Contacts:Ms. Camille
Contacts:Mr. 方

Copyright © 2024 Easun Power Technology Corp LimitedTodos os direitos reservados.

Enviar Inquérito
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

enviar